Safe QLD is a full scope sprinkler contractor. We design to the AS 2118 series, draft and coordinate the installation, commission and certify the system, then hold the ongoing AS 1851 maintenance contract. Wet and dry systems, in-rack and high-bay warehousing, cold storage, high-rise residential and multi-site portfolios.

AS 2118 Design & Install AS 1851 Maintenance Contracts QBCC Licence 1143420 24/7 On Call · 2hr Response
Full Scope Sprinkler Contractor

From Hydraulic Concept to the Five-Yearly Routine, One Contractor

Most fire companies service sprinkler systems. Fewer can build one. With over 60 years experience, Safe QLD has been a main part of fire protection compliance throughout South East Queensland, and our sprinkler capability runs the full length of an asset's life: engineering the design, drafting the layouts and block plans, project managing the installation, commissioning it methodically, certifying it, then maintaining it to AS 1851 for the next twenty years.

That matters when a system needs more than a test sheet. Upgrading a warehouse from ordinary hazard to in-rack protection, extending a live sprinkler main through an occupied floor, replacing a corroded valve set on a tenanted high-rise, or rectifying a defect schedule handed down after a certifier's audit are engineering jobs, not service calls. Because our design, drafting, installation, commissioning and maintenance teams sit under one roof, the person who calculates the hydraulics is in the same business as the technician who returns to flow test it.

AS 2118.1 Sprinkler Systems AS 2118.4 Residential AS 2118.6 Combined Systems AS 1851-2012 AS 2941 Fire Pumpsets NCC/BCA QBCC Licence 1143420

🏗️

Design & Engineering

Hydraulic design to the AS 2118 series, hazard classification, density and area of operation, water supply assessment and coordination with the hydraulic consultant, certifier and builder.

📐

Drafting & Planning

Coordinated shop drawings, pipework and head layouts, valve room arrangements, block plans and as-built documentation ready for handover and the maintenance file.

🔧

Installation & Upgrades

Full sprinkler installation, extensions, relocations for fitouts, valve set replacement, in-rack retrofits and staged upgrades in live buildings by our own installation fleet.

🧪

Commissioning & Certification

Methodical commissioning, hydrostatic and flow testing, alarm and monitoring verification, and the certification documentation your certifier and insurer require.

🗓️

AS 1851 Maintenance

Monthly, six-monthly, annual and five-yearly sprinkler routines run as a scheduled contract across single sites or an entire portfolio, with one reporting standard.

🚨

Defects & Breakdowns

24/7 on call across the Gold Coast to Sunshine Coast corridor with a 2 hour response for tripped valves, leaking heads, pressure loss and impaired systems.

System Types

Wet, Dry, In-Rack and High-Rise, Built for the Hazard in Front of Us

Red sprinkler and fire pump room pipework installed and maintained by Safe QLD Fire Protection

Wet and Dry Pipe Sprinkler Systems

Whether pumped or un-pumped, Safe QLD has the equipment and expertise required to service your sprinkler systems, hose reels, hydrants and water tanks. With a fleet of service and installation technicians we can cater to your needs, from a single valve set to a fully pumped multi-stage installation.

  • Wet pipe systems for offices, retail, healthcare, warehousing and residential
  • Dry pipe systems for freezer rooms, cold storage and exposed or unheated areas, including trip testing and air pressure maintenance
  • Pre-action and combined sprinkler and hydrant systems under AS 2118.6
  • Pumped systems with fire pumpsets, water storage tanks and diesel or electric drivers
  • Town main supplies, boosters and supply pressure verification
  • Zone isolation arrangements planned so future works do not shut a whole building down

Selecting the right system is a design decision, not a catalogue choice. We classify the hazard, model the water supply and specify the arrangement that meets AS 2118 and the NCC for that building, then build it.

Large industrial warehouse building of the type protected by in-rack and high-bay sprinkler systems installed by Safe QLD

In-Rack and High-Bay Protection for Warehousing and Cold Storage

Racked storage changes everything about a sprinkler design. Storage height, commodity classification, rack configuration, flue spaces and aisle widths drive the density, the head selection and whether ceiling-only protection is even permitted. Get it wrong and the system is non-compliant the day the racking is reconfigured.

  • In-rack sprinkler design, installation and modification for high-bay racking
  • ESFR and control mode head arrangements assessed against storage arrangement
  • Cold storage and freezer applications using dry systems where required
  • Sprinkler relocation and infill when racking layouts or occupancy change
  • Protection of loading docks, canopies, plant rooms and mezzanines
  • Coordination with detection, EWIS and special hazard suppression on the same site

We already work across the cold chain in South East Queensland, including a QLD Health cold storage hub, a food distribution centre in Logan and seafood processing on the Gold Coast, so the constraints of a live temperature controlled facility are familiar ground.

Fire hydrant and sprinkler booster assembly with pressure gauges serviced by Safe QLD Fire Protection

Residential, High-Rise and Strata Sprinkler Systems

Apartment towers carry a sprinkler system that has to work quietly around hundreds of residents. Valve sets sit in basements and risers, flow switches report by floor, and any isolation has to be planned to the minute. Safe QLD maintains and upgrades residential sprinkler systems for bodies corporate and building managers across Brisbane and the wider SEQ region, including works completed at Parkside Apartments in Brisbane.

  • AS 2118.4 residential sprinkler systems and AS 2118.1 high-rise installations
  • Floor by floor flow switch and isolation valve testing with monitoring verification
  • Riser, valve set and stop valve replacement in occupied towers
  • Sprinkler head replacement in apartments scheduled around resident access
  • Defect rectification following building audits and insurer inspections
  • Single point of contact for the committee, building manager and caretaker
Valve Sets & Components

The Parts of a Sprinkler System That Actually Fail

A sprinkler system is only as reliable as its control valves, alarm valves, flow switches and heads. Most sprinkler defects we are called to are not exotic, they are a closed isolation valve nobody logged, a seized alarm valve, a flow switch that no longer reports to the panel, or heads painted over during a fitout. Our routines target exactly those failure points, and our routines target exactly those failure points so they are found before they matter.

Alarm Valves & Valve Sets

Inspection, testing, servicing, overhaul and full replacement of wet and dry alarm valves, main stop valves, non-return valves and the associated trim, gauges and drains. Valve room housekeeping and labelling brought back to standard.

Flow Switches & Monitoring

Flow switch operation verified through the test valve, alarm transmission to the fire indicator panel confirmed, and signal receipt confirmed with the monitoring company so every zone reports where it should.

Isolation & Stop Valves

Position, strapping, locking and monitoring of every isolation valve checked and recorded. Valves exercised, reseated or replaced, and any valve found closed is reported immediately as an impairment.

Sprinkler Heads & Stock

Painted, corroded, loaded, damaged or leaking heads replaced like for like. We carry common types, temperature ratings, response classes and escutcheons, plus the spare head stock and wrench your valve room is required to hold.

Block Plans & Documentation

Accurate, current block plans and system schematics drafted and mounted in the valve room, along with as-built drawings, hydraulic data and the AS 1851 baseline data your maintenance program depends on.

Pipework & Supports

Corrosion, leaks, seismic and hanger support defects, obstructed heads and unauthorised alterations by other trades identified, quoted and rectified, including pipework modification for fitouts and racking changes.

Sprinkler system impaired, valve tripped, or heads damaged during works? An impaired sprinkler system is a live risk to your building and your insurance position. Safe QLD is on call 24/7 with a 2 hour response from the Gold Coast to the Sunshine Coast, call (07) 3286 6310.
AS 1851-2012 Routines

Your Sprinkler Maintenance Calendar, Level by Level

AS 1851-2012 does not treat a sprinkler system as one annual visit. It layers four routines on top of each other, each digging further into the system, and each generating records that your annual occupier statement relies on. Safe QLD schedules all four across your site or portfolio so the annual and five-yearly work is planned and budgeted well before it falls due.

RoutineWhat is carried outWhy it matters
Monthly Visual inspection of the valve enclosure, confirmation that all control and isolation valves are open, strapped and monitored, gauge pressures on the water supply and system sides recorded, water supply availability confirmed, pumpset and tank status checked where fitted. Catches the single most common cause of sprinkler failure, a closed or unmonitored valve, and detects pressure loss before it becomes a defect.
Six-Monthly Alarm testing through the test valve on each alarm valve and zone, flow switch operation and transmission to the fire indicator panel, monitoring signal receipt confirmed with the monitoring company, valve set operation and trim checked, pumpset routines where applicable. Proves the system can actually raise an alarm and get a signal to the brigade, not just hold water.
Annual Full system inspection including water supply flow test and pressure readings against the design data, sprinkler head condition survey, pipework, hangers and supports, obstruction and clearance checks, valve operation, spare head stock verified, block plans and records reviewed against the installed system. Confirms the water supply still delivers the flow and pressure the system was designed around, and that no fitout or racking change has compromised coverage.
Five-Yearly Internal inspection of pipework for corrosion, scale and obstruction, valve overhaul and internal inspection, valve overhaul, gauge verification and internal pipework inspection, water supply and tank inspection, pumpset overhaul items, and a comprehensive report on system condition and remaining service life. The deep service. It finds internal corrosion and degraded heads that no external inspection can see, and is where most major rectification budgets originate.

Frequencies and the exact scope of each routine depend on the system type, its classification and the arrangement installed. Dry, pre-action and pumped systems carry additional routines, including dry valve trip testing and diesel pumpset running under AS 2941. We set the correct schedule against your system during the baseline survey rather than applying a generic template.

Working in Live Buildings

Controlled Isolations, Coordinated With Monitoring

Night works fire system installation with crane access, carried out by Safe QLD outside tenant operating hours

The System Comes Back Online Before We Leave Site

Sprinkler work in an occupied hospital, shopping centre, cold store or apartment tower cannot be improvised. Every isolation is an impairment, and an unmanaged impairment is an insurance and life safety exposure. Safe QLD runs a controlled procedure on every job that touches a valve.

  • Scope, affected zones and expected duration agreed with the building manager before the day
  • Monitoring company and the relevant authority notified before isolation and again on restoration
  • Isolation kept to the smallest zone possible, with tagging and an impairment watch maintained while the system is down
  • Hot works and adjacent trades coordinated so the impaired period is not extended
  • System restored, valves reopened, strapped and pressure confirmed, alarms and flow switches re-tested before sign off
  • After hours and staged night works where tenancy, theatre lists or production schedules demand it

This is the same discipline we apply on hospital and healthcare projects for Queensland Health Metro South, a regional hospital ward upgrade and a private day surgery, where a sprinkler zone cannot simply be turned off for the afternoon.

Proven Capability

The depth to hold a major sprinkler contract

60+
Years Combined Experience
6
In-House Disciplines
24/7
On Call Across SEQ
2hr
Response, Gold Coast to Sunshine Coast
How a Sprinkler Project Runs

Six In-House Disciplines, One Accountable Contractor

Design & Engineering

Hazard classification, hydraulic design to AS 2118, water supply assessment and coordination with the hydraulic consultant, engineer and certifier on the project.

Drafting & Planning

Shop drawings, head and pipework layouts, valve room arrangements and block plans, coordinated against structure, services and racking.

Project Management & QA

Programme, procurement, site coordination, ITPs and hold points managed by a dedicated project manager so the builder gets one point of contact.

Specialist Installation

Our own QBCC licensed installation and electrical technicians install pipework, valve sets, flow switches and monitoring interfaces to the approved design.

Methodical Commissioning

Hydrostatic and flow testing, alarm and monitoring verification, defect close out and the certification documentation required for handover.

Service & Maintenance

The system rolls straight into a scheduled AS 1851 maintenance contract with the same business that built it, and the same digital reporting.

Common Questions

Fire Sprinkler System FAQs

How often does a fire sprinkler system need to be tested?
AS 1851-2012 sets a layered routine. Monthly covers valve positions, gauge pressures and water supply availability. Six-monthly covers alarm and flow switch testing and monitoring transmission. The annual routine adds flow testing of the water supply and a full system inspection. The five-yearly routine covers internal pipework inspection, valve overhaul and sprinkler head sampling. Safe QLD schedules all four levels in one program so the deeper routines are planned and budgeted rather than arriving as a surprise.
Can sprinkler maintenance be done without shutting a tenanted building down?
Yes. The vast majority of sprinkler routines are carried out live. Where an isolation is genuinely required, we work to a controlled isolation procedure: the monitoring company and the relevant authority are notified before the valve is closed, the affected zone and duration are agreed with the building manager in advance, the isolation is kept to the smallest zone possible with an impairment watch maintained, and the system is restored and re-tested before we leave site. Where tenancy, clinical or production schedules demand it, we work after hours.
What is the difference between a wet and a dry sprinkler system?
A wet pipe system holds water in the pipework at all times, so a fused head discharges immediately. A dry pipe system holds the pipework under air or nitrogen pressure behind a dry valve, and water only enters once a head operates and the valve trips. Dry systems are used where pipework is exposed to freezing or extreme conditions, such as freezer rooms and parts of cold storage facilities. They carry additional obligations under AS 1851, including dry valve trip testing and air pressure maintenance, which we build into the maintenance schedule.
When do sprinkler heads need to be replaced?
Heads are replaced when they are painted, corroded, loaded with dust or debris, physically damaged, leaking, or when five-yearly sample testing indicates the batch is no longer performing. Heads are never repaired, cleaned aggressively or repainted. We hold stock of common head types, temperature ratings and response classes so replacements happen on the visit instead of leaving the system impaired while parts are ordered, and we make sure the spare head stock and wrench required in your valve room are actually there.
Can Safe QLD design and install a new sprinkler system, not just maintain one?
Yes. Safe QLD runs six in-house disciplines across major works: Design and Engineering, Drafting and Planning, Project Management and QA, Specialist Installation and Programming, Methodical Commissioning, and Service and Maintenance. We design to the AS 2118 series and the NCC, produce the drafting and block plans, coordinate with the hydraulic consultant and certifier, install and commission the works, then hold the ongoing AS 1851 maintenance contract. New builds, extensions, fitout modifications, in-rack retrofits and full system upgrades are all in scope.
Do you take on multi-site and whole-of-building maintenance contracts?
Yes, and that is where we work best. A single contract can cover sprinklers, fire pumps and water storage, hydrants and hose reels, detection, EWIS and occupant warning, emergency and exit lighting, passive fire, and yes, extinguishers and blankets as well. One schedule, one reporting standard, one set of records for every site in the portfolio, and no gaps between contractors arguing over whose asset a defect belongs to.