Whether pumped or un-pumped, Safe QLD has the equipment and expertise required to service your sprinkler systems, suppression systems, hose reels, hydrants and water tanks. Our fleet of service and installation technicians keeps your water-based fire protection tested, compliant and ready to perform.
Water-based fire protection is your building's heavy artillery. Sprinklers control a fire automatically, hydrants give QFES crews the water they need, and hose reels put first-attack capability in the hands of your occupants. Safe QLD services all of them under a single AS 1851-2012 maintenance program, with one schedule, one digital report and one point of contact.
AS 1851-2012 AS 2118 Sprinklers AS 2419 Hydrants NCC/BCA QFES QBCC Licence 1143420
Monthly inspections, annual full system tests and five-yearly assessments of automatic sprinkler and special hazard suppression systems designed to AS 2118, including alarm valve, flow switch and head condition checks.
Monthly visual inspections, six-monthly functional tests, annual flow testing and five-yearly overhauls of hydrant systems designed to AS 2419, including booster assemblies, block plans and signage.
Six-monthly inspections under AS 1851-2012 covering accessibility, hose condition, nozzle operation and full run-out and rewind tests, with on-the-spot repairs or replacement where needed.
Monthly pump runs under load, battery, fuel and driver checks, tank water level and condition inspections, and annual performance testing against the pump's rated duty point.

Your hydrant system only matters on one day, the day QFES connects to your booster. Safe QLD tests hydrant systems the way they will actually be used, verifying flows and pressures at the hydrant landing valves and booster connections against the design figures on your block plan.
Every test is captured in a detailed digital compliance report, so you have audit-ready evidence of exactly what was tested, what passed and what needs attention.

Safe QLD sees water-based first-attack equipment as a quintessential component of a safe occupancy. Our technicians service hose reels and sprinkler systems on the same visit as your hydrants, which means fewer site attendances, less disruption and a single consolidated report.
Pumped or un-pumped, town main or tank-fed, our fleet of service and installation technicians can cater to your site's needs anywhere from the Gold Coast to the Sunshine Coast.
AS 1851-2012 sets fixed routines for every water-based system. Miss one and your annual occupier statement is at risk. Here is what Safe QLD schedules and delivers for you, automatically.
| Frequency | Sprinkler Systems | Hydrants & Boosters | Hose Reels, Pumps & Tanks |
|---|---|---|---|
| Monthly | System inspection, control valves, gauges and alarms | Visual inspection of hydrants, boosters and cabinets | Pump runs under load, tank level and condition checks |
| Six-Monthly | Interim checks and defect follow-up | Functional testing of landing valves and hydrant operation | Hose reel inspection, run-out and flow check |
| Annual | Full system test, water flow, alarms, obstruction and corrosion checks | Flow testing against AS 2419 design performance | Pump performance test against rated duty |
| Five-Yearly | Comprehensive assessment, pipe flushing and sprinkler head checks | Overhaul, replacing landing valves, check valves and gauges | Major service and component overhaul as required |
Monthly, six-monthly, annual and five-yearly AS 1851 testing of fire panels, detection and occupant warning systems by QBCC licensed technicians.
Explore detection & alarmsSix-monthly extinguisher inspections, five-yearly pressure testing and reliable portable equipment from Australia's top manufacturers.
Explore portable equipmentIn-house design, drafting, installation and commissioning of sprinkler, hydrant and pump systems for new builds and major works across SEQ.
Explore construction servicesFast response across South East Queensland. Clear digital reports. Audit-ready compliance.