24/7 ON CALL QBCC Licence 1143420 · CM3 Prequalified Service@SafeQLD.com.au (07) 3286 6310
Home / Services / Extinguishers, Blankets & Signs

Fire Extinguishers, Blankets, Hose Reels & ID Signs

Portable fire fighting equipment is a quintessential component of a safe occupancy. Safe QLD supplies, installs and services extinguishers, fire blankets, hose reels and identification signage across Brisbane and South East Queensland, with every service completed to AS 1851-2012.

Six-monthly AS 1851 testing Five-yearly pressure testing QBCC licensed technicians 24/7 on call
Portable Fire Equipment

The first line of defence in every building

A correctly selected, correctly located and correctly maintained extinguisher is often the difference between a small incident and a building fire. Safe QLD sees portable fire fighting equipment as a quintessential component of a safe occupancy, and our relationships with Australia's top manufacturers allow us to provide the most reliable equipment at affordable prices.

From a single extinguisher in a small office to group-wide equipment programs across multi-site portfolios, our QBCC licensed technicians supply, install, test and tag every unit, keep your logbooks and digital records audit-ready, and flag defects early so they never become expensive problems.

AS 1851-2012 Section 10 AS 2444 NCC/BCA Building Fire Safety Regulation 2008 QBCC Licence 1143420
🧯

Fire Extinguishers

Supply, installation, six-monthly inspections, five-yearly pressure testing, recharging and replacement of all extinguisher types.

🧵

Fire Blankets

Kitchen and workshop fire blankets supplied and installed to AS 2444, inspected on the same six-monthly cycle as your extinguishers.

🚒

Fire Hose Reels

Six-monthly hose reel inspections to AS 1851-2012, checking accessibility, hose condition and operational readiness.

🪧

ID & Location Signs

Compliant identification and location signage for every item of equipment, including child-safe height and access requirements for education sites.

Choose The Right Unit

Types of fire extinguishers and what they fight

Using the wrong extinguisher can make a fire worse. Under AS 2444, extinguisher selection must match the fire risks in each area of your building. Here is the quick guide our technicians work from every day.

Extinguisher TypeBand ColourBest ForNever Use On
WaterAll red, no bandClass A fires: wood, paper, textiles and other ordinary combustiblesElectrical equipment, cooking oils, flammable liquids
FoamBlue bandClass A and Class B fires: flammable liquids such as petrol, paint and solventsEnergised electrical equipment
CO2 (Carbon Dioxide)Black bandClass E electrical fires: switchboards, server rooms, plant and office equipmentOutdoor or windy areas where gas disperses; deep fat fryers
ABE Dry ChemicalWhite bandClass A, B and E fires: the most common general purpose unit for offices, warehouses and vehiclesCooking oil fires, sensitive electronics where residue is a concern
Wet ChemicalOatmeal bandClass F fires: cooking oils and fats in commercial kitchensEnergised electrical equipment
Not sure what you need? Safe QLD will assess the fire risks in each area of your site and recommend the right mix, locations and signage to satisfy AS 2444 and the Building Code of Australia. Assessments are free with any quote.
Routine Servicing

Six-monthly inspections to AS 1851-2012

Fire hose reel installed on an industrial building serviced by Safe QLD

What our technicians check, every visit

In Queensland, fire safety equipment maintenance is governed by the Building Fire Safety Regulation 2008 and AS 1851. Extinguishers, blankets and hose reels all require six-monthly inspections, and every result is recorded so your building stays audit-ready.

  • Six-monthly extinguisher inspections (AS 1851-2012 Section 10), checking location, access and visibility
  • Anti-tamper seals, safety pins and discharge hoses checked and replaced where needed
  • Pressure gauge readings verified, with CO2 units weighed to confirm contents
  • Cylinder condition inspected for corrosion, dents and damage
  • Fire blankets and hose reels inspected for accessibility, condition and operational readiness
  • Identification signs checked and rectified to AS 2444
  • Service tags stamped and results logged in your digital compliance report
Deeper Maintenance

Pressure testing, recharging and replacement

Safe QLD technician testing equipment showing system normal

Five-yearly testing that keeps cylinders safe

Beyond the six-monthly cycle, AS 1851-2012 requires every extinguisher to be pressure tested and refilled every five years, or immediately after any use. Pressure testing verifies the integrity of the cylinder itself, so it performs safely when it matters most.

  • Five-yearly hydrostatic pressure testing of extinguisher cylinders (AS 1851-2012)
  • Recharge and refill after any discharge, however small
  • Replacement units supplied where cylinders fail test or reach end of life
  • Loan and exchange units available so your building is never left unprotected
  • Only qualified personnel should service extinguishers, and all Safe QLD work is completed by QBCC licensed technicians

Every test, recharge and replacement is captured in your maintenance records, because failure to keep compliant records can lead to enforcement notices from QBCC or Fire Safety Officers.

How It Works

Simple, scheduled, sorted

Site Audit

We assess your building's fire risks and existing equipment against AS 2444 and AS 1851, and quote clearly with no surprises.

Supply & Install

Equipment from Australia's top manufacturers, installed with compliant brackets, signage and locations.

Scheduled Servicing

Six-monthly inspections and five-yearly pressure testing, scheduled automatically so nothing is ever missed.

Digital Reporting

Detailed digital compliance reports with defects flagged early, giving you full audit traceability.

Common Questions

Fire extinguisher FAQs

How often should fire extinguishers be inspected and tested?
Fire extinguishers must be inspected every six months under AS 1851-2012 Section 10. They also require pressure testing and refilling every five years, or immediately after any use. Every service is recorded on the unit's service tag and in your maintenance records so your compliance trail is complete.
When should fire extinguishers be pressure tested?
Pressure testing is required every five years, or after any use, as per AS 1851-2012, to verify the integrity of the cylinder. Safe QLD manages the whole cycle for you, including loan units so your building is never left without coverage while cylinders are away for testing.
What types of fire extinguishers are available, and which should I use?
Common types include ABE dry chemical (Class A, B and E fires), CO2 (ideal for electrical fires), foam (effective on flammable liquids), water (Class A combustible materials) and wet chemical (cooking oils and fats). The right mix depends on your building's risks. Safe QLD assesses your site and recommends compliant coverage under AS 2444.
Is it mandatory to have fire extinguishers in commercial buildings?
Yes. Under the Building Code of Australia and AS 2444, appropriate fire extinguishers must be installed based on the building's fire risk assessment. In Queensland, the Building Fire Safety Regulation 2008 also requires occupiers to keep that equipment maintained to AS 1851, and only qualified personnel should carry out the servicing.
Keep Exploring

Related fire protection services

Is your building due for its AS 1851 fire service?

Fast response across South East Queensland. Clear digital reports. Audit-ready compliance.

📞 Call Safe QLD: (07) 3286 6310