Fire Detection & Alarm System Testing & Maintenance

Safe QLD's service and maintenance team meets 24/7 compliance and maintenance requirements from the Gold Coast to the Sunshine Coast within a 2-hour service response. Monthly, six-monthly, annual or five-yearly, our QBCC licensed technicians are ready to meet your AS 1851 requirements.

24/7 on call 2-hour response, Gold Coast to Sunshine Coast QBCC licensed technicians Digital compliance reports
AS 1851 Section 6

Fire alarm servicing that keeps your building audit-ready

Your fire detection and alarm system is the first line of defence for everyone in the building. AS 1851-2012 Section 6 sets out a strict routine of inspections and tests, and Safe QLD delivers every one of them, on schedule, with clear digital records that stand up to any audit.

  • Monthly functional checks of warning devices and visual indicators (AS 1851-2012 Section 6)
  • Six-monthly inspections of detectors, panels and batteries (AS 1851-2012 Section 6)
  • Annual full-system testing with fault simulations, evacuation tones and battery capacity checks (AS 1851-2012 Section 6)
  • Five-yearly comprehensive inspection and system verification (AS 1851-2012)
  • Design, installation and upgrade compliance to AS 1670.1 and NCC/BCA
  • Fault diagnosis and proactive maintenance to prevent battery failures, dirty detectors, wiring faults and false alarms
AS 1851-2012AS 1670.1NCC/BCAQFES
Safe QLD technician testing a fire indicator panel showing system normal
Systems We Service

From single panels to networked EWIS and aspirating detection

Our technicians work across the full range of detection and warning systems installed in South East Queensland buildings, including legacy panels other providers walk away from.

🔥

Fire Indicator Panels (FIP)

Conventional and addressable fire indicator panels inspected, tested and repaired, with zone diagrams and logbooks kept current.

📢

EWIS & Occupant Warning

Emergency warning and intercom systems and occupant warning systems tested for evacuation tones, speech intelligibility and staged evacuation sequences.

💨

VESDA & Aspirating Smoke Detection

Very early smoke detection apparatus and ASD systems serviced for critical environments such as cold storage, healthcare and data rooms.

🛠️

Securitron Systems

Securitron detection panels maintained and repaired by technicians who know the platform, keeping older installations compliant.

⚙️

Wagner Systems

Wagner detection systems inspected and tested to the same AS 1851 routines, with parts sourced and defects rectified promptly.

🔔

Detection Devices & Call Points

Smoke and thermal detectors, manual call points and sounders tested as a complete system, as AS 1670.1 requires components to work together.

Testing Schedule

Your AS 1851-2012 Section 6 routine at a glance

Whether it be monthly, six-monthly, annual or five-yearly, our team schedules every interval for you so nothing slips through the cracks.

IntervalWhat happens
Monthly Functional checks of the fire indicator panel, warning devices and visual indicators. Panel condition, fault lamps and event history reviewed and logged.
Six-monthly Inspection and test of detectors, manual call points, batteries and connections. Defects identified, recorded and quoted for rectification.
Annual Full-system testing including fault simulations, evacuation tones, interface checks to other fire systems, and battery capacity testing.
Five-yearly Comprehensive inspection and verification of the complete detection and warning system, with detector performance confirmed and end-of-life components programmed for replacement.
Records matter. Under AS 1851, every routine inspection and test must be recorded with dates, results, defects found and corrective actions. Safe QLD provides digital and hard-copy maintenance reports for full audit traceability, so an enforcement notice from QBCC or a Fire Safety Officer is never a surprise.
FAQs

Fire detection & alarm questions, answered

How often must fire detection and alarm systems be tested?
Fire detection and alarm systems must be tested in accordance with AS 1851-2012 Section 6, which requires monthly functional checks such as testing warning devices and visual indicators, six-monthly inspections, and annual full-system testing including fault simulations, evacuation tones and battery capacity checks. Safe QLD provides comprehensive testing programs that meet all AS 1851 obligations, contact our Service Manager to book a service.
What standard governs the design and installation of fire alarm systems in commercial buildings?
Fire alarm system design and installation must comply with AS 1670.1, which covers the layout, detector spacing, cabling, power supply, panel configuration and required documentation. We work with engineers and builders to ensure systems we install or maintain meet both AS 1670.1 and NCC/BCA fire protection performance criteria.
Are smoke detectors alone compliant for fire alarm systems?
No. While smoke detectors are essential, a compliant fire detection system often includes thermal detectors, manual call points, sounders and control panels, especially in Class 2 to 9 buildings. As per AS 1670.1, system components must work together to detect, alert and activate evacuation where required. Safe QLD audits and upgrades legacy systems to ensure compliance.
What records must be kept for fire alarm maintenance?
Under AS 1851, all routine inspections and tests must be recorded in a logbook or digital maintenance record. This includes test dates, results, defects found and corrective actions. Failure to keep compliant records can lead to enforcement notices by QBCC or Fire Safety Officers. Safe QLD provides digital and hard-copy maintenance reports for full audit traceability.
Related Services

Complete the compliance picture

Emergency & Exit Lighting

Six-monthly discharge testing and annual inspections to AS 2293, delivered by our specialist electrical contractors.

Explore emergency lighting

Sprinklers, Hydrants & Hose Reels

Water-based systems serviced to AS 1851, from monthly checks through to five-yearly hydrant overhauls and flow tests.

Explore sprinklers & hydrants

Compliance & AS 1851

What building owners and managers are responsible for under AS 1851-2012, and how Safe QLD keeps you covered.

Understand your obligations

Is your building due for its AS 1851 fire service?

Fast response across South East Queensland. Clear digital reports. Audit-ready compliance.

📞 Call Safe QLD: (07) 3286 6310