Safe QLD's service and maintenance team meets 24/7 compliance and maintenance requirements from the Gold Coast to the Sunshine Coast within a 2-hour service response. Monthly, six-monthly, annual or five-yearly, our QBCC licensed technicians are ready to meet your AS 1851 requirements.
Your fire detection and alarm system is the first line of defence for everyone in the building. AS 1851-2012 Section 6 sets out a strict routine of inspections and tests, and Safe QLD delivers every one of them, on schedule, with clear digital records that stand up to any audit.

Our technicians work across the full range of detection and warning systems installed in South East Queensland buildings, including legacy panels other providers walk away from.
Conventional and addressable fire indicator panels inspected, tested and repaired, with zone diagrams and logbooks kept current.
Emergency warning and intercom systems and occupant warning systems tested for evacuation tones, speech intelligibility and staged evacuation sequences.
Very early smoke detection apparatus and ASD systems serviced for critical environments such as cold storage, healthcare and data rooms.
Securitron detection panels maintained and repaired by technicians who know the platform, keeping older installations compliant.
Wagner detection systems inspected and tested to the same AS 1851 routines, with parts sourced and defects rectified promptly.
Smoke and thermal detectors, manual call points and sounders tested as a complete system, as AS 1670.1 requires components to work together.
Whether it be monthly, six-monthly, annual or five-yearly, our team schedules every interval for you so nothing slips through the cracks.
| Interval | What happens |
|---|---|
| Monthly | Functional checks of the fire indicator panel, warning devices and visual indicators. Panel condition, fault lamps and event history reviewed and logged. |
| Six-monthly | Inspection and test of detectors, manual call points, batteries and connections. Defects identified, recorded and quoted for rectification. |
| Annual | Full-system testing including fault simulations, evacuation tones, interface checks to other fire systems, and battery capacity testing. |
| Five-yearly | Comprehensive inspection and verification of the complete detection and warning system, with detector performance confirmed and end-of-life components programmed for replacement. |
Six-monthly discharge testing and annual inspections to AS 2293, delivered by our specialist electrical contractors.
Explore emergency lightingWater-based systems serviced to AS 1851, from monthly checks through to five-yearly hydrant overhauls and flow tests.
Explore sprinklers & hydrantsWhat building owners and managers are responsible for under AS 1851-2012, and how Safe QLD keeps you covered.
Understand your obligationsFast response across South East Queensland. Clear digital reports. Audit-ready compliance.